Design and installation of liftable tube type microporous aerator

Views: 202 Author: Site Editor Publish Time: Origin: Site

1. In the design and application of the liftable tube type microporous aerator, the left and right spacing of the air intake manifold floating on the water is 1000~3000mm, between the aerator and the aerator on the straight line of each air intake manifold The distance is 500~1500mm; the specific distance depends on the water concentration, water quality, air supply and other process conditions.

2. This aerator can be used for single-head air intake if there are 10 sets on each DN100 air intake branch line; if there are more than 10 sets, two-head air intake can be used. The specific number of sets depends on the air. It depends on the flow rate.

3. Each inlet branch pipe shall be distributed from the main pipe on the bank of the pool, and a valve shall be installed and bend against the pool wall to the water level in the pool.

4. The aerator is suspended and installed about 150~500mm away from the bottom of the tank, or according to design requirements.

5. The exchange connection port of each intake branch pipe is connected by a special rubber tube, such as the height of the water level, there is no effect.

6. The price of this aerator is based on the set, responsible for on-site installation.


×